Winding Deformation Detection of Transformer Based on Sweep …

judge the deformation of transformer winding by measuring the change of leakage inductance [12]. The test principle diagram is shown in Fig. 1. The method has simple test procedure, convenient measurement, good repeatabil-ity, and high reliability of detecting

Effect of transformer winding mechanical defects, …

In this paper, the winding mechanical defects of the transformers, including radial deformation (RD) and axial displacement …

Sweep frequency response analysis

In addition to that, there are turn-to-turn capacitors (an ideal capacitor and the loss component) and turn-to-ground capacitors. Power transformer internal faults can produce shifts in some regions of the frequency response curve, and these shifts can be identified by visual inspection.

An Experimental Study of the Sweep Frequency Impedance Method on the Winding Deformation …

Power transformers are one of the most important devices in electrical networks. The safety operation of the transformers directly affects the reliability of the power system. To diagnose the internal deformation of the transformer as soon as possible is of great significance. As a new technique, sweep frequency impedance (SFI) method has …

Theoretical considerations while applying sweep …

This paper systematically investigates on theoretical and practical aspects of frequency response analysis method in evaluating …

Research on Winding Deformation Detection and Diagnosis …

Timely and effective measurement of transformer winding deformation can effectively prevent further deterioration of ... Comparison of Relevant Standards for Winding Deformation Test by Frequency ...

Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in …

Test research on power transformer winding deformation by FRA method electrical insulating materials (ISEIM 2001) IEEE Proceedings of 2001 International Symposium, 19–22 November ( 2001 ), pp. 837 - 840

Research on large-capacity impulse test technology for …

After the test, carry out short-circuit impedance test and winding deformation test on the test form, and the change rate of short-circuit impedance before and after the test shall not exceed 0.2%. The change rate of winding capacitance is less than 0.45%, and the test result of winding deformation has no noticeable change …

Transformer Winding Deformation Diagnostic System Using …

Winding Deformation Diagnostic System Using Online High Frequency Signal Injection DOI 10.1109/TDEI.2014.004283 ... transformer winding, bushing test tap was used to inject signal into the ...

Sweep Frequency Response Analysis Test | SFRA Test of …

SFRA Test can detect, winding deformation – axial & radial, like hoop buckling, tilting, spiraling displacements between high and low voltage windings partial winding collapse shorted or open ...

The actual measurement and analysis of transformer winding deformation …

In order to carry out the analysis based on mathematical statistics method, the FRA data of actual transformer winding deformations should be obtained at first. In our previous study [7, 19], a specially manufactured transformer was built up and used for winding deformation fault simulation tests, a large number of tests have been carried …

Frequency Response Analysis

HV winding often shifts axially with respect to the LV winding, as shown schematically in Fig. 7.19a, under the influence of the axial electromagnetic forces []. The electrical parameters affected most by this type of deformation are inter-winding capacitance and

Partial Discharge Testing: A Progress Report PD

Compliance with IEC 60270 [23] for stator windings is unnecessary. IEC 60270 is only valid for capacitive test objects. A stator winding is not a capacitance. It is a complex inductive – capacitive circuit. Instead, IEC 60034-27-2 [25] is appropriate since it is

Summary of Transformer Winding Deformation Detection and …

This paper summarizes and compares various methods of transformer wind-ing deformation diagnosis. First, the principle and characteristics of the trans-former …

A test method of winding deformation excited by pseudorandom …

In order to implement the test method to detect winding deformation excited by pseudorandom binary M-Sequences (The M-Sequence method), a detecting instrument for winding deformation synthetically based on the M-Sequence method and Frequency Response Analysis (FRA) is developed. Three kinds of the artificial failures aimed to …

Applying Sweep Frequency Response Analysis and Leakage Reactance to Determine Mechanical Faults …

If the transformer is not a two-winding unit, then the test plan will vary. Shown below are additional test plan architectures that include three-winding and auto-transformer configurations. • 2 Winding (H, X) 3-H OC 3-X OC 3-HX SC • 3 Winding (H, X

Sensors | Free Full-Text | Research on On-Line …

Simulation results of three types of winding faults: (a) Frequency response curve of overall winding axis offset; (b) Frequency response curves of winding radial deformation from 20 MHz to 26 MHz; …

Testing and Diganostics of Power Transformers Brochure

6 TESTRANO 600 CPC 100 CPC 80 + CP TD1 TANDO 700 DIRANA FRANEO 800 CT ANALYZER MPD 600 PDL 650 Capacitance and power factor/dissipation factor measurement: at 50 Hz or 60 Hz 1 4 as tip-up test 1 4 with variable frequency 1 4 ...

On-site transformer diagnostic measurements: The art of …

It is recommended to measure the resistance for all taps of the OLTC.The resistance values should be corrected to 75 C according to IEC 60076 Part 1. Reference: Test report of the manufacturer, fingerprint measurements. Interpretation: The measured winding resistance should not differ more than about 1% compared to the factory test …

Research on On-Line Detection Method of Transformer Winding Deformation …

Sensors 2021, 21, 7386 2 of 18 Domestic and foreign scholars have done a lot of research on the detection of trans-former winding deformation and formed the following several mature detection methods. The short-circuit impedance method [5–7] has been

Radial stability evaluation and cumulative test of transformer winding…

In Fig. 2, q is the load and u is the deformation of the conductor. For transformer windings, buckling failure often precedes strength failure. The winding may face instability under the huge radial force, and the critical stress of the winding may be far less than the limit ...

Leakage Reactance Manual

Doble Engineering Company 85 Walnut Street Watertown, Massachusetts 02472-4037 (USA) PN 500-0396 72A-2243-01 Rev. B 9/04 September 17, 2004 72A-2243-01 Rev. B 9/04 iii September 17, 2004 Preface Structure of this Manual This manual consists of 4

Dry Film Capacitors for High-Frequency Power …

This article discusses the requirements for power capacitors in systems seeking advantage in state-of-the-art high-frequency designs. Dry plastic-dielectric (film) capacitors provide high-reliability …

A Comprehensive Guide to Doble Testing

• Capacitance test to measure any physical change that might harm the apparatus • Leakage reactance/short circuit impedance testing to evaluate winding deformation (with the optional Doble M4110) • Excitation current tests to make sure that transformer''s ...

Diagnosis and Analysis of the Transformer Winding Deformation …

a variety of test methods 66kV transformer winding deformation, and the advantages and disadvantages of these test methods are discussed in detail, based on capacitance …

Leakage Reactance Manual

Several methods have been used to detect winding deformation. They are: • frequency response analysis • Iow-voltage impulse test • capacitance measurement • leakage reactance measurement Methods one and two have inherently very promising searching

Winding deformation classification in a power transformer based …

To calculate the geometric capacitance of the windings, the energy method and FEM are used. The series capacitor of each winding consists of the turn-to-turn …

Transformer winding deformation diagnostic system using online …

This paper aims at proposing a novel diagnostic system for online monitoring power transformer winding deformation based on FRA. In order to realize …

Transformer Winding Deformation Diagnostic System Using …

Transformer winding deformation is common among all sorts of transformer failures. Cumulative deformation can eventually burgeon into catastrophic faults and result in …

Transformer Winding Deformation Diagnostic System Using …

Each section of high voltage (HV) distributed transformer winding is represented as inductance LSH and series resistance RSH, shunt capacitance in between two-turn represented as CSH and a ...

Detection of transformer winding faults using FRA and image …

The frequency response analysis (FRA) is known as an advanced diagnostic approach to detect winding faults in a transformer due to its sensitivity and repeatability [4–6]. When …

Methodology to locate and quantify radial winding deformation in power transformers

Emulating the change in capacitance due to buckling of the LV winding requires the ability to reduce the HV to LV winding capacitance and increase the LV to core capacitance. The capacitance between the HV and LV windings of a transformer can be estimated by treating it as a cylindrical capacitor (Fig. 3 ).